Whole Plasmid and Amplicon Sequencing Sample Submission Guidelines
Whole Plasmid Sequencing
- GENEWIZ Drop Box or Fridge – Place your samples and a copy of your order form in a GENEWIZ drop box or fridge before the cut-off time. Call 1-877-436-3949 for your nearest GENEWIZ drop-off location.
- GENEWIZ Courier Service – Request for courier pickup if available at your location. Please call 1-877-436-3949 to find out if a GENEWIZ courier picks up at your site. For San Diego customers within the pickup zone, specify the pickup location when placing your order. Note that GENEWIZ couriers pick up room temperature samples only.
-
If a drop box or courier is not available, and for International shipments, ship your samples via overnight delivery service (FedEx if possible) to us at the following location:
GENEWIZ from Azenta
115 Corporate Blvd.
South Plainfield, NJ 07080
USA
908-222-0711
Plasmid-EZ (Whole Plasmid Sequencing)
| Sample Type | Quantity | Quality | Shipping Temperature |
|---|---|---|---|
| Plasmid DNA* Water, EB, Low TE buffer (0.1mM EDTA) |
Minimum Amount: Quantity: ≥500 ng Volume: ≥10 µL Concentration: 50 ng/µL Normalized |
A260/A280 = 1.8-2.0 | Ambient or blue ice |
Bacteria
|
|
|
|
Colony-EZ (Whole Plasmid Sequencing from Bacteria)
| Sample Type | Quantity | Quality | Shipping Temperature |
|---|---|---|---|
| Bacterial Colonies Bacteria* BSL1 specimens only |
1 colony per well submitted in a 96-well agar stab plate | 1 well-grown colony per well (incubated for at least 8h) | Ambient or blue ice |
| Liquid Culture Bacteria* BSL1 specimens only |
10-50 µL of an overnight culture (8-16h) submitted in 96-well plates (we will inoculate an overnight culture before proceeding with Plasmid-Prep) 500 µL of an overnight culture (8-16h) submitted in 96-well plates (we will directly proceed with Plasmid Prep) |
Samples should be visibly cloudy | Ambient or blue ice |
| Glycerol Stock Bacteria* BSL1 specimens only |
100ul of glycerol stock | Samples should be visibly cloudy | Dry ice |
Colony-EZ Plus (Whole Plasmid Sequencing from Bacteria)
| Sample Type | Quantity | Quality | Shipping Temperature |
|---|---|---|---|
| Bacteria Colonies on agar | Circle and number colonies or leave blank for random pick. | Individual colonies should be widely spaced on agar plate | Ambient or blue ice |
| Liquid Culture | 100ul of overnight-grown liquid culture (8 to 16 hours) | Samples should be visibly cloudy | Ambient or blue ice |
| Glycerol Stock | 100ul of glycerol stock | Samples should be visibly cloudy | Dry ice |
*Colony-EZ Plus is recommended for customers who require deeper coverage in their sequence, particularly for difficult plasmids. Process involves mini prep of samples prior to extraction to assist. Please expect 1 additional business day for results. Additional charges apply.
Oxford Nanopore Amplicon Sequencing
- GENEWIZ Drop Box or Fridge – Place your samples and a copy of your order form in a GENEWIZ drop box or fridge before the cut-off time. Call 1-877-436-3949 for your nearest GENEWIZ drop-off location.
- GENEWIZ Courier Service – Request for courier pickup if available at your location. Please call 1-877-436-3949 to find out if a GENEWIZ courier picks up at your site. For San Diego customers within the pickup zone, specify the pickup location when placing your order. Note that GENEWIZ couriers pick up room temperature samples only.
-
If a drop box or courier is not available, and for International
shipments, ship your samples via overnight delivery service (FedEx if
possible) to us at the following location:
GENEWIZ from Azenta
115 Corporate Blvd.
South Plainfield, NJ 07080
USA
908-222-0711
PCR-EZ (Long-Read PCR Product Sequencing)
| Sample Type | Quantity | Quality | Shipping Temperature |
|---|---|---|---|
|
Unpurified and Purified PCR Products Water, EB, Low TE buffer (0.1mM EDTA) |
Minimum Amount: Quantity: ≥500 ng Volume: ≥10 µL Concentration: 50 ng/µL Normalized |
A260/A280 = 1.8–2.0 | Ambient or blue ice |
PCR-EZ Max (Full-Length, Long-Read PCR Product Sequencing)
| Sample Type | Quantity | Quality | Shipping Temperature |
|---|---|---|---|
|
Unpurified and Purified PCR Products Water, EB, Low TE buffer (0.1mM EDTA) |
Minimum Amount: ≥100 ng in 10 µL (10 ng/µL) per 1 kb amplicon is required (i.e. a 4 kb amplicon requires 400 ng in 10 µL at 40 ng/µL) |
A260/A280 = 1.8–2.0 RNA-free |
Ambient or blue ice |
Amplicon-Based Next Generation Sequencing
Direct Shipping (FedEx):
Please use an overnight delivery service such as FedEx for all NGS samples. A printout of the confirmed quote must be included with the material. View our Sample Submission Best Practices Checklist .
All Amplicon-based Next-Gen Sequencing (except for Amplicon-EZ) direct shipments should be sent to:
GENEWIZ from Azenta Life Sciences
Attn: NGS
111 Corporate Boulevard
Suite H Loading Dock
South Plainfield, NJ 07080
USA
All Amplicon-EZ direct shipments should be sent to:
GENEWIZ from Azenta Life Sciences
115 Corporate Boulevard
South Plainfield, NJ 07080
USA
Tubes / Plates
Organize your samples in tubes or plates following the order indicated on the sample submission form.
Tubes: Prepare samples in clearly labeled and well-organized 1.5 mL flip-cap microcentrifuge tubes. Please avoid using Parafilm to seal the tubes.
Plates: For projects with 16 or more samples, prepare samples in clearly labeled, securely sealed 96-well full-skirted PCR v-bottom plates. Arrange the samples vertically by column (i.e. A1, B1, C1, etc.)
Quality control (QC) is conducted using Qubit (not Nanodrop) and TapeStation. QC results will determine the most suitable approach based on sample quantity and quality.
Illumina Amplicon Sequencing
| Sample Type | Quantity | Quality | Shipping Temperature |
|---|---|---|---|
|
Genomic DNA Double-Stranded* Water, EB, low TE buffer (0.1mM EDTA) |
Preferred Amount: Quantity: ≥250 ng Volume: 25-50 µL Concentration: 10 – 50 ng/µL Minimum Amount: Quantity: 150 ng Volume: >25 µL Concentration: ≥6 ng/µL |
A260/A280 = 1.8-2.0 DIN >5.0 RNA-free |
Dry ice |
*Purified and unpurified amplicons, restriction digested material, fragmented DNA, and plasmids accepted.
PacBio Amplicon Sequencing
| Sample Type | Quantity | Quality | Shipping Temperature |
|---|---|---|---|
|
Amplicon DNA* Low TE buffer (0.1mM EDTA) |
Preferred Amount: Quantity: ≥2 µg Volume: ≥20 µL Concentration: ≥50 ng/µL Minimum Amount: Quantity: ≥1 µg Volume: ≥20 µL Concentration: ≥50 ng/µL |
A260/A280 = 1.8-2.2 A260/A230 = ≥2.0 RNA-free |
Dry ice |
*Purified and unpurified amplicons, restriction digested material, and plasmids accepted. Additionally, we can prepare an amplicon from a wide range of starting materials, including genomic DNA, cell pellets, and tissue material. Please see the Extraction Requirements section for further details.
Custom TargetGxOne™ Amplicon Sequencing
| Sample Type | Quantity | Quality | Shipping Temperature |
|---|---|---|---|
|
Genomic DNA Double-stranded Water, EB, Low TE buffer (0.1mM EDTA) |
Preferred Amount: Quantity: ≥250 ng Volume: 25-50 µL Concentration: ≥10 ng/µL Minimum Amount: Quantity: 100 ng Volume: ≥25 µL Concentration: ≥4 ng/µL |
A260/A280 = 1.8-2.0 DIN >7.0 RNA-free |
Dry ice |
Amplicon-EZ (AMP-EZ)
| Sample Type | Quantity | Quality | Shipping Temperature |
|---|---|---|---|
|
Purified PCR Products Water, EB, Low TE buffer (0.1mM EDTA) |
Minimum Amount: Quantity: ≥500 ng Volume: ≥25 µL Concentration: 20 ng/µL Normalized |
A260/A280 = 1.8-2.0 | Ambient or blue ice |