About Sequencing Only Service

What Sequencing Only services does GENEWIZ offer?

We offer high-throughput next generation sequencing (NGS) on pre-made NGS libraries using Illumina® platforms.

What type of pre-made libraries can I submit?

You can submit any Illumina®-compatible library for sequencing. If the library preparation used Illumina® adapters during ligation, these will be successfully sequenced using GENEWIZ’s Sequencing Only service.

What is the size range of pre-made libraries that I can submit?

You can submit libraries up to 600 bp.

Do you offer next generation sequencing of pre-made libraries on platforms other than Illumina®?

Yes, we offer next generation sequencing of pre-made NGS libraries on other NGS platforms, including long-read platforms. Please contact the team by submitting an inquiry.

Can you spike PhiX into my sequencing run?

Yes, please instruct our team what percentage of PhiX spike-in to use, and we’ll accommodate the request free of charge. See the following recommendations of PhiX spike-in:

  • ~20% taxon identification (ITS/16S/18S) and WGBS
  • ~30% amplicon and small RNA libraries
  • ~5%-10% low diversity libraries

Please indicate that you require data analysis upon submitting your instant quote.

PhiX spike-in

Do you accept libraries with custom sequencing or index primers?

Yes, please indicate that your libraries have custom sequencing or index primers upon submitting your instant quote.

Custom-sequencing-or-index-primers

What sequencing configurations are available?

There are several Illumina® sequencing configurations available including 2×150 bp, 2×250 bp, 2×300 bp, and 10x sequencing.

GENEWIZ has a variety of sequencers, offering different amounts of data output:

  • 2×150 bp configuration: MiSeq flow cell (4.5 Gb), NovaSeq X Plus 10B flow cell (3,000 Gb), NovaSeq X Plus 25B lane (950 Gb), NovaSeq X Plus 25B flow cell (7,600 Gb)
  • 2×250 bp configuration: MiSeq flow cell (7.5 Gb), NovaSeq 6000 SP flow cell (325-400 Gb)
  • 2×300 bp configuration: MiSeq flow cell (13 Gb)
  • 10x sequencing only: NovaSeq X Plus 25B lane (950 Gb), NovaSeq X Plus 25B flow cell (7,600 Gb)
What is a flow cell?

A flow cell is a glass or polymer slide used in NGS platforms (like Illumina®) where DNA fragments are immobilized, amplified, and sequenced. It contains multiple lanes or channels that can be loaded with different DNA libraries.

What is a dedicated lane/flow cell?

A dedicated lane/flow cell means ordering and utilizing the entire lane of a flow cell or the entire flow cell. The lane/flow cell is dedicated to your individual project, maximizing throughput and minimizing cross-contamination risk.

partial-or-dedicated-lane-flow-cell

What is a partial lane/flow cell?

A partial lane/flow cell refers to using only a subset of the lane of a flow cell. The remaining lanes may be used for other projects or pooled with other users’ samples. This is often called lane sharing or multiplexing across lanes. This option is only available for 2×150 bp configuration.

partial-or-dedicated-lane-flow-cell

There are several data packages available: 105 Gb, 375 Gb. The data package will be assigned based on the total number of libraries, amount of data per library, and amount of PhiX spike-in required.

When would you use a dedicated lane/flow cell?
  • Large-scale projects needing high read depth
  • Clinical or regulatory-grade sequencing where contamination must be avoided
  • Require sequencing configuration outside of 2×150 bp (i.e. 2×250 bp, 2×300 bp)
  • Require specific Illumina sequencing platform to keep continuity for publication purposes
When is a partial lane/flow cell more appropriate?
  • Smaller projects with fewer samples needing less than 950 Gb of data output
  • Cost-conscious sequencing where full lane/flow cell capacity isn’t needed
  • Sequencing configuration of 2×150 bp
Is there a risk of sample mix-up in partial flow cells?

The risk is minimal, but possible. GENEWIZ has an optimized and efficient process of pooling samples from different projects to ensure the highest quality and chain of custody.

Do both options use the same sequencing chemistry?

Yes, the sequencing chemistry remains the same. The difference lies in how the lane/flow cell is allocated and utilized.

What is the price for Sequencing Only?

Please submit a quote request to receive accurate pricing information, as the cost depends on the details of the project. Please submit an inquiry to inquire about your specific project needs.

Partial lane/flow cell runs are less total money because you pay for a smaller data package. Dedicated lane/flow cell runs are more expensive but more cost-effective by cost per Gb.

Technical Design

What does it mean to be a standard Illumina-compatible library?

Illumina®-compatible libraries require four major components in their adapter sequences, found at the ends of each fragment, for paired-end sequencing:

  • Flow cell binding sites. Known as P5 or P7, they facilitate clustering of the DNA strands on the flow cell.
  • Sequencing primer binding sites. Labeled as Read 1 and Read 2, they are necessary to initiate sequencing at both ends of the fragment.
  • Index sequences. Often called i5 and i7, they act as barcodes to allow multiplexing (pooling) of samples. Libraries can be either single index (having one index sequencing) or dual index (having two index sequences), and each library to be pooled requires at least one unique index.
  • Index primer binding site(s). These are required to read the index sequences.

The composition of the adapter sequences depends on whether the library is single or dual indexed (see figure below). If any of the components are missing, heavily modified, or in the wrong configuration, sequencing may fail. If you have any questions regarding your library configuration, please contact us.

Single-Indexed Sequencing

Dual-Indexed Sequencing

Please indicate what type of indexed sequences (index primer binding sites) your pre-made libraries contain upon submitting your instant quote.

index-primer-binding-site

index-primer-binding-site2

What index sizes can be accepted?

GENEWIZ can accept sequencing libraries with index configurations of 6 bp (most single index applications), 8 bp (most dual index applications), 10 bp, and 16 bp. Other custom index options are available. Please submit an inquiry for more details.

Data Analysis

Can GENEWIZ de-multiplex my data?

Yes, we will provide the de-multiplexing step free of charge. We ask that you provide the index sequences in the Sample Submission Form prior to your sequencing run.

Can GENEWIZ perform de-multiplexing of “in-line” barcodes in sequencing reads?

Yes, we offer de-multiplexing of in-line barcodes in sequencing reads (not index reads). Additional charges may apply.

Please indicate that you require de-multiplexing of “in-line” barcodes upon submitting your instant quote.

barcodes

special-comments

Can you perform data analysis for my Sequencing Only project?

Yes, we offer a variety of data analysis services across all applications including whole genome sequencing, RNA sequencing, single-cell sequencing, exome sequencing, epigenomics, metagenomics, immunogenomics, and proteomics.

Please indicate that you require data analysis upon submitting your instant quote.

data-analysis

special-comments

General Questions

How do I contact GENEWIZ for a technical consultation about my project?

The GENEWIZ NGS Team is composed of Ph.D. scientists who can help you optimize your project design and provide consultation. You can contact the team by submitting an inquiry.

Does GENEWIZ guarantee turnaround?

Our team prioritizes fast turnaround times and provide a timeline based on first-pass processing. The turnaround time listed within the quote is inclusive of all steps quoted, unless otherwise noted. If repeat processing is required, the turnaround may be subject to change and will be proactively communicated to the client.

If the scope of a project changes after project initiation or if sample or project clarification is required after sample receipt, GENEWIZ may reassess the turnaround time based on the subsequent communications and modifications (if applicable).

What extraction methods are used?

All extraction kits and reagents are routinely updated to remain best-in-class. Please proactively contact GENEWIZ if you would like historical versions, which may be available on a case-by-case basis.

Extractions are performed to the best of our ability and are unable to guarantee yield due to multiple variables that may affect sample yield and quality. Costs to cover the work performed will be applied, regardless of the outcome.

What library preparation methods are used?

All library kits and reagents are routinely updated to remain best-in-class. Please proactively contact GENEWIZ if you would like historical versions, which may be available on a case-by-case basis.

Does GENEWIZ perform sample QC and what methods are used?

For most of the services, an initial sample QC is included within the fee of the project for all samples that will proceed to the next processing stage (e.g. library preparation or sequencing) unless otherwise noted within the quotation. Resubmissions or additional, optional samples may incur a nominal fee for QC.

Most services include an initial sample QC within the project fee for samples proceeding to the next stage (e.g., library preparation or sequencing). Resubmissions or additional samples may incur a small QC fee unless noted otherwise in the quotation.

Initial sample QC can include:

  • Assessing RNA concentration and integrity
  • Assessing DNA concentration and DNA size (for select projects)
  • Assessing premade library size and concentration
  •  
  • Assessing cryopreserved cells by cell count and viability
What sequencing instruments will be used for my project?

The sequencing platform will be listed within the Service Description of the quotation.

 

Unless specifically noted in the quotation, GENEWIZ reserves the right to choose between equivalent instruments depending on the target read depth and configuration requested. If a specific instrument is required, please add special comments in your quote/order and notify our NGS team prior to project initiation.

How does GENEWIZ guarantee data quality and yield?

Illumina-based projects

For samples that pass QC and libraries prepared at GENEWIZ:

Data Quality

  • NovaSeq 2x150bp: ≥85% of bases ≥Q30
  • NovaSeq 2x250bp: ≥80% of bases ≥Q30
  • MiSeq 2x150bp: ≥80% of bases ≥Q30
  • MiSeq 2x250bp: ≥75% of bases ≥Q30

Data Yield

  • Within 10% of total data target yield per lane or flowcell, unless otherwise noted
  • Within 20% of per sample target yield, unless otherwise noted

Quality and yield for samples that do not pass QC and are processed at best effort are not guaranteed. Premade libraries/library pools submitted for sequencing only quality and yield are evaluated on a case-by-case basis.

 

Multiplexing is performed to the best of our ability to ensure relatively even data distribution amongst samples.

PacBio-based projects

Due to various sample-related factors that may influence long-read sequencing yield and quality, GENEWIZ cannot guarantee overall data output and quality. However, based on extensive experience with long-read workflows, GENEWIZ has established target metrics based on the PacBio system based on the sample submitted and library type. If a project does not meet these targets, a thorough review of the processing will be performed. If the issue is determined to be unrelated to the sample, a repeat or top-off will be performed as necessary.

What is GENEWIZ’s coverage guarantee?

Due to the possible wide range of performance being influenced by sequence complexity and sample quality, GENEWIZ does not guarantee average coverage or on-target specificity for each sample. We can instead recommend target data output that would increase the chances of obtaining the desired coverage based on the sample and library type utilized.

What is GENEWIZ’s data analysis guarantee?

Data analysis is performed to the best of our ability and results are not guaranteed for samples or libraries not passing QC or do not fit the analysis pipeline’s criteria.

Can you recommend the best data delivery option?

Yes, we can recommend the best data delivery option based on the platform and project details. Options include:

  • Secure File Transfer Protocol (sFTP) – additional charges may apply
  • Customer Cloud Account – AWS, Microsoft Azure, Google Cloud
  • Hard Drive – additional charges may apply
How will my data be delivered?

By default, results are sent via a secure File Transfer Protocol (sFTP). Please refer to our sFTP Data Download Guide for instructions on how to download your data and troubleshooting tips. Additional charges may be applicable for large data transfers.

Please refer to the delivery email sent from GENEWIZ for detailed information on the transfer and consult with your IT department to ensure compliance with your institution’s policies.

Will my data be secure at GENEWIZ?

We take data security very seriously and we make every attempt to keep your data private and protected. The data transfer we offer is secure; however, should you desire an alternative delivery method, we are happy to work with you.

How long does GENEWIZ store samples?

We hold any remaining samples for up to 3 months after project completion. Clinical samples processed in our Regulatory-Environment or CLIA-licensed laboratory may have longer sample storage timelines. Please contact us if you would like samples retained for a longer period or shipped back to you.

How long does GENEWIZ store data?

GENEWIZ offers raw data storage (i.e. FASTQ for Illumina, BAM for PacBio, POD5 for Oxford Nanopore) for up to 6 months after project completion. Data generated for samples processed in the Regulatory-Environment or CLIA-licensed laboratory may have longer data retention timelines. Please contact us if you would like the data to be retained for a longer period. 

Sample Preparation

How should I prepare and send my samples?

View our Sample Submission Guidelines for instructions on preparing and sending samples. Organize your samples in tubes or plates following the order indicated on the sample submission form.

  • Tubes: Prepare samples in clearly labeled and well-organized 1.5 mL flip-cap microcentrifuge tubes. Please avoid using Parafilm to seal the tubes.

Icon_460x305_Tubes_48Samples

Unless otherwise instructed, GENEWIZ reserves the right to combine multiple vials of the same sample for extraction and/or library preparation.

  • Plates: For projects with 16 or more samples, prepare samples in clearly labeled, securely sealed 96-well full-skirted PCR v-bottom plates. Arrange the samples vertically by column (i.e. A1, B1, C1, etc.)

Icon_460x305_Plates_48Samples

Ship samples directly to our facility. Use the shipping address listed on the order receipt.

What can I do if my samples do not meet the starting material requirements?

Please reach out to us by submitting an inquiry.

Order & Processing

How do I request a quote?

Request a quote through your GENEWIZ account. Click on the service you’d like to order.

How do I confirm a quote?

Log into your GENEWIZ account to confirm your quote.

How can I monitor the progress of my project?

The status of your order, including an estimated date of delivery, can be viewed anytime through your GENEWIZ account. Visit the Order Summary page of your project to find the current order status.

How can I send my samples to GENEWIZ?

Option #1: Ship samples directly to our facility. Use the shipping address listed on your order receipt.

  

Option #2: For double-stranded DNA samples, submit samples into a local GENEWIZ dropbox which are conveniently located throughout the US, Europe and United Kingdom. To locate a dropbox near you, please submit an inquiry. Place your order receipt and samples in a Ziploc bag packaged according to sample submission guidelines specific for your Next Generation Sequencing service. 

  

Note: Not recommended for RNA and primary sample types. 

  
What are the cutoff times for my dropbox pickup?

During checkout, consult the Order Summary page to find out the daily cutoff times for your selected dropbox (see example below).

image-13

If you miss the dropbox deadline, feel free to ship samples directly to us.